Uniwell px 5700 operation manual




















Press this key before scalable PLU key is pressed if necessary. Enters into Scroll Display Mode during a transaction and scrolls up or down the previously registered items on the display. TTL 25 key is fixed as a local currency media. Page Operation Sequences VI. When the optional Clerk iButton System was selected, other methods clerk code, Hard clerk key, clerk card can not be used. Page Clerk Interrupt System 3. Page Floating Clerk Interrupt 4. Floating Clerk Interrupt Almost all operations are same as the normal clerk interrupt system.

Page Plu 5. Bar Coded PLUs can be programmed and registered by a scanner. Procedure: Scan the bar code labeled on each item while the control key is at the R position. When [SF Maximum sales quantity and stock of PLU is One is used for the normal preset price and the other is used for happy hour price, service price, etc. This is limited to 20 link PLUs. In other words, max. PLU programmed by [PF It can be entered only with a main PLU. Each modifier key is given a 3- digit modifier value left one digit shows value, right two digits show number of digit.

Select "PLU modifier permitted" This function is especially useful for the bar since simply registering the single item PLU close the transaction automatically. There are two types of single item transactions as follows: Single-item 1: This can be used as normal registration with other non-single items and will not automatically close the transaction.

The cooking message can be either preprogrammed one of 50 messages or manually entered. The cooking message is printed under the PLU line on the receipt. The price is calculated by entered weight and unit price of scalable PLU. If scale is not fitted for USA scale type, manual weight entry is always available.

When the item is placed on the scale and the PLU is entered, the PLU will have an actual price calculated by the weight. It is done either by using programmable 99 tare tables or by entering a tare weight manually. Tare weight should be entered before entering scalable item. Also, when the tare weight is larger than item's weight, warning message 93 will be displayed. Following example shows a case when HAM 40g was entered, amount 0.

The items are neither registered as a sale nor printed on a receipt. Page Kitchen Printer 6. In the clerk interrupt system, when a clerk's transaction is interrupted, the registered items are transmitted to the kitchen printer when [SF The quantity and PLU name are printed in double-width characters.

Page Media Closing 7. Media Closing Up to 25 different media total keys can be used to close a transaction. In addition to these media keys, there are 10 preset tender keys, which have preset tendering amounts by programming, available to close a transaction by one-action.

Page B Currency Exchange b Currency Exchange In order to exchange a foreign currency to the local currency, enter the foreign currency amount and press F. Media key at the beginning of a transaction. When a transaction is closed by Euro media key, the due amounts in local and Euro currencies are printed on the receipt. If taxable items are included in the transaction, the Euro taxable amount and tax are also printed separately from the local taxable amount and tax.

Page 51 2. Page Tip Operation Tip Operation A tip amount can be entered as either an amount separate from payment or as change from over-tendering. Mark-up and Mark-down are presettable on each item, saving the trouble of manually entering rates. Adjustment amounts are shown on the full transaction report, but they will not affect PLU sales memory. The key operation determines whether the amount is added to the item or subtotal.

Page Last Item Correction Last Item Correction CR key is used to cancel the last-registered item including function key. Press CR key immediately after the wrong item or the wrong function key is registered. The corrected item is never printed on the post-receipt, kitchen printer and slip printer.

In order to void an item registered by a series of key depression, the same key operation must be repeated. Scroll Void voids all these additional entries on the PLU automatically. Select an item you wish to void and press VOID key. Press CR key to cancel the void selection. Page Transaction Void Transaction Void Transaction Void can be done if you wish to cancel all the registrations in a transaction.

This is available only before the transaction is closed. The ECR will not check to see if the refunded item was actually registered except the case of item track operation before the track is closed by a media key.

Refund all items. Press SBTL key. Page 65 Media Refund This function is useful when you wish to refund a registered item in the transaction closed by plural media keys. It is not required to do if the transaction was closed by one media key. By this operation, the refunded amounts are subtracted from the respective media memory, but they are not memorized in the refund memory.

Page Tax The tax shift is available however, manual tax amount entry and manual tax exemption are not available. Page No Sale No Sale This function is used to open the drawer outside of sales. Page Number Of People Additional entry is overridden not added. Page Message Page Slip Validation Tp Only Validation on the slip printer is available if the ECR is programmed for use with a slip printer TP Page Arrangement Arrangement There are four kinds of arrangement keys.

Page Recall A transaction which has been closed with amount tendered can not be recalled. The recalled transaction must be closed by a media key with a tendering amount entry. It can be canceled by CL key. For Amount Track System, the track number must always be entered manually. Page Item Track System A. Page 84 i Always entire Check-Out Bill is printed on new slip.

Page 85 iii Additional registrations are always printed as a continuation of the previous Subtotal Bill. I need a manual for the Uniwell cash register. I can't change the program. My uniwell sx is asking for an initial reset. How do I do this? Graham November I have uniwell sx that give me error of CID please help me to remove akhilesh December Our LX is currently displaying only?????????

Uniwell seem to give you operation but not programming manuals. I needed a DX manual. Good luck Richard G May I have uniwell sx I have not used for thr last two years and now it is on but will not do any things and the key do not function can you help thanks jamal August Miguel F April Peter February Which model do you have? The collective have many Uniwell manuals. COM Registerman September I can answer this question Uniwell manual?

Your Answer:.