Giotto spot 400 manual
Remove the cover in the direction indicated by the arrow Fig. Unscrew the two threaded pins 1 2 as shown in Fig. Swivel the whole block downwards Fig. Page Installing The Lamp 2. Open the fixture see paragraph 1. When fitting a lamp, always use gloves or soft lint-free cloth - never touch it with your bare hands.
Page Lamp Alignment Dichro: After opening the fixture, locate the gobo to be replaced, press delicately downwards Fig.
Install the new gobo 3 as shown Fig. Carefully widen the discs again 3 and slide the new filter in 4 until it fits into its engraved slot.
Giotto Spot CMY rel. Up to eight fixtures can be upgraded simultaneously. In the selected menu, used to change the required parameters. The message on the display will start to flash. The total number of hours the lamp has been lit will be displayed automatically. Browse by Category Clear Selection. Cable Management Retractable Reels. Laser Lights Blisslight Lasers. Tools Applicators Industry Specific. Absolute Lumens.
Akg Acoustics. Bss Audio. City Theatrical. Crown International. Equipson Sa. Interactive Technologies. Jbl Professional. Kre Electric. In fact, only the recipient can claim for any damage caused to the fixture during transport. ATTENTION: make certain that the fixture is switched off and that there is no risk of burns due to high component temperature wait at least 30 minutes after switching off To access internal components, proceed as follows: 1. Loosen the two screws shown in Fig. Remove the cover 1 in the direction indicated by the arrow Fig.
Unscrew the two threaded pins 5 6 as shown in Fig. Swivel the whole block downwards Fig. Follow the following instructions when installing a lamp or relamping. Disconnect the power supply, put on protective gloves and eyewear. Open the fixture see paragraph 1. When fitting a lamp, always use gloves or soft lint-free cloth - never touch it with your bare hands.
Install the new lamp par. Connect the fixture to a lighting console. Point the fixture at a flat surface if possible white or light colored at least three metres from the fixture. Set the control channels to obtain a white beam. Use screws 1, 2 and-3 to align the lamp until an evenly projected light beam is obtained, with no shadows or zones which are brighter than others. Install the new gobo 1 as shown Fig. Dichro: After opening the fixture, locate the gobo to be replaced, press delicately downwards Fig.
Install the new gobo 3 as shown Fig. Open the disks 3 and remove the spring C. Carefully widen the discs again 3 and slide the new filter in 4 until it fits into its engraved slot. The following design shows how to connect the connector to the cable, whereas the table shows the symbols normally used to indicate connections. When in doubt, consult a qualified electrician. Fix the fixture to the support structure using safety chains fitted to the 2 holes on the underside of the fixture's base Fig.
Don't fix the safety chain to the handles. Screened cables in compliance with EIA RS specifications and the following characteristics must be used for connections: - 2 conductors plus screen - Ohm impedance - low capacitance - max. Example of connection of the DMX line To avoid the risk of faulty operation, follow these indications: Maximum cable length: metres Max. Nof fixtures connected: 32 Cable runs: Avoid running cables alongside power supply lines.
Termination: A Ohm resistor between Pins 2 and 3 on the last fixture. Connectors must always be 5-pin XLRs. Refer to the diagram for wiring.
In fact, it's possible to assign the start address; obtain information regarding lamp life and fixture operation time; run test programs to check correct fixture operation and customize some parameters. The 3 keys under the display are for selecting and using the various submenus which make up the main menu. In the selected menu, used to change the required parameters. Stores lamp elapsed time.
Can be reset. Stores the number of lamp strike. Stores fixture operating time. EN Remote reset enabled. Used according to the position in which the fixture is installed. Range sec Its possible to set the number of second for which the fixtures last operating status must be held when there is no DMX signal.
This address normally indicates the first channel used start channel and can be allocated following a different criterion from that used to connect the signal line. Giotto Spot uses 22 controls channels, so during allocation, this quantity must be borne in mind to avoid possible overlapping of other fixtures' channels, which would cause problems with the perfect control of all the available functions.
Should it be necessary, it's possible to allocate the same start channel to several fixtures, in this case the fixtures will all follow the same commands, but can't be controlled separately.
To address fixtures correctly, proceed as follows: 1. Connect Giotto Spot to the power supply, wait until it has completed reset operations and DMX signal appears on the display.
The message on the display starts to flash. To modify Pan movement, proceed as follows: 1. Connect the Giotto Spot to the power supply, wait till it has completed reset operations and DMX signal appears on the display. The message on the display will start to flash.
To limit Pan movement, proceed as follows: 1. Connect Giotto Spot to the power supply, wait till it has completed reset operations and DMX signal appears on the display. Fixture N. Start Channel Fixture N. To modify Tilt movement, proceed as follows 1. To limit the Tilt movement, proceed as follows: 1. This is necessary to know in advance when it's almost time for relamping: lamp life is approximately hours. To see how many hours a lamp has been used, proceed as follows: 1. The total number of hours the lamp has been lit will be displayed automatically.
To reset the elapsed time meter, proceed as follows: 1. The DOWN key can be used to reset the meter. On the contrary, pressing the UP key restores the previous value. This information is important because needless lamp strikes causes stress to materials and components, so can contribute to reducing lamp life.
To know how many times a lamp has been ignited: 1. The number of lamp strikes will be displayed automatically. To reset the meter, proceed as follows: 1. This meter cannot be reset.
0コメント